Volume 2, Issue 2 (September- 2013)                   Caspian J Dent Res 2013, 2(2): 23-28 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mirzaie M, Arash V, Rabiee M, Ramezani I, Bijani A. Evaluation of frictional resistance between monocrystalline (ICE) brakcets and Stainless Steel, Beta TMA and NiTiarch wires. Caspian J Dent Res 2013; 2 (2) :23-28
URL: http://cjdr.ir/article-1-83-en.html
,Dental Materials Research Center, Faculty of Dentistry, Babol University Medical Sciences, Babol-Iran. , im_ramezani@yahoo.com
Abstract:   (13820 Views)

Introduction: When using sliding mechanics for space closure during orthodontic treatment, friction occurs at the bracket-wire interface. The aim of this study was to evaluate the frictional resistance between monocrystalline (ICE) brackets and Stainless Steel, Beta TMA and NiTi wires.

Methods: In this experimental study, we used 5 different types of orthodontic wires. Brackets and wires were divided in to 5 groups: 1-(monocrystalline+stainless steel 18) 2–(monocrystalline+stainless steel 19×25) 3-(monocrystalline+Beta-TMA) 4–(monocrystalline+Beta TMA 19×25) 5-(monocrystalline+NiTi 18). Instron Universal Testing Machine was used to investigate the static frictional resistance. The angulation between bracket and wire was 0 and the wires were pulled through the slots at a speed of 10 mm/min. Tests were performed 10 times for each group in artificial saliva. The average of 10 forces recorded was considered as static friction. One-way ANOVA and SPSS Version 18 and LSD post hoc test were used to evaluate the results of the study.

Results: The mean static frictional force for each group was: group1: 0.82 ± 0.14, group 2: 1.09 ± 0.30, group 3: 0.87 ± 0.53, group 4: 1.9 ± 1.16, group 5: 1.42 ± 0.30. There was a significant difference when comparing the two groups of similar wires in terms of shape (round or rectangular cross-section) as when comparing Beta TMA 18 and 19×25 arch wires with each other, the obtained p-value was 0.023, while the obtained p-value for the comparison of stainles steel arch wires was 0.034 .

Conclusions: The result of this study shows that Stainless Steel 18 wires generate the least amount of friction and round wires produce less friction than the rectangular wires. Beta TMA wires generate the highest amount of friction.

Full-Text [PDF 531 kb]   (3605 Downloads)    
Type of Study: Research Paper | Subject: Orthodontics
* Corresponding Author Address: Faculty of Dentistry, Babol University Medical Sciences, Babol-Iran.

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Caspian Journal of Dental Research

Designed & Developed by : Yektaweb