Volume 9, Issue 2 (September- 2020)                   Caspian J Dent Res 2020, 9(2): 16-25 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Amiri Daneshvar F, Alhavaz A, Ahmadizenouz G, Bijani A. Effect of three veneering techniques on fracture resistance and marginal adaptation of zirconia-based crowns. Caspian J Dent Res 2020; 9 (2) :16-25
URL: http://cjdr.ir/article-1-288-en.html
,Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, IR Iran. , gazalehahmadidds@gmail.com
Abstract:   (4301 Views)
Introduction: The aim of this study was to evaluate the fracture resistance (FR) of zirconia-based crowns veneered with different methods and to assess marginal gap before and after veneering.
Materials & Methods: Thirty zirconia copings fabricated by Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) were divided into three groups. In the porcelain layering (PL) group, the copings were manually veneered with VM9 feldspathic porcelain. In the indirect composite (IC) group, the Gradia indirect composite was veneered on zirconia copings, and for the CAD-on (CO) group, the CAD/CAM-fabricated Vita Mark II veneer was cemented onto the copings. For each sample, the marginal gap values at four points (buccal, lingual, mesial and distal) were measured using stereomicroscope and computer software (Motic Images plus 2.0 ML) before and after veneering process. All crowns were cemented on their dies with resin cement and then were loaded by a universal testing machine for failure. Data were analyzed using one-way ANOVA and post-hoc Tukey tests at significant level of 0.05.
Results: Mean FR was statistically higher in PL group (3005 N) than IC (2026 N) and CO (1605 N) groups (P=0.000). Before and after veneering, mean marginal gap was 43.42μm and 48.47μm for PL group, 44.69μm and 51.06μm for IC group as well as 53.03μm and 56.08μm for CO group, respectively. Marginal gap had no significant difference in study groups before and after veneering (P=0.56 and 0.18, respectively). The lowest change in marginal gap was observed in CO group.
Conclusion: The PL technique might increase the failure resistance of Zirconia-based crowns compared to IC and CO techniques. The marginal gap rate following veneering in all three techniques was within acceptable clinical limits.
Full-Text [PDF 1083 kb]   (1837 Downloads)    
Type of Study: Research Paper | Subject: Prosthodontics
* Corresponding Author Address: Department of Restorative Dentistry, Faculty of Dentistry, Babol University of Medical Sciences, Babol, IR Iran.

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Caspian Journal of Dental Research

Designed & Developed by : Yektaweb