<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Caspian Journal Of Dental Research</title>
<title_fa>مجله تحقيقات دندانپزشكي كاسپين</title_fa>
<short_title>Caspian J Dent Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://cjdr.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-9890</journal_id_issn>
<journal_id_issn_online>2322-2395</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/cjdr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی مقایسه ای رادیوپاسیته ی دیجیتال سمان های دندانی</title_fa>
	<title>Comparative study of digital radiopacity of dental cements</title>
	<subject_fa>پروتزهای دندانی</subject_fa>
	<subject>Prosthodontics</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Paper</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;مقدمه: &lt;/b&gt;&lt;/span&gt;رادیواپاسیته یک خاصیت ضروری برای سمانهای دندانپزشکی میباشد . هدف این مطالعه بررسی رادیواپاسیته تعدادی ازسمانهای مورداستفاده درپروتزهای دندانی میباشد .&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;موادوروش &lt;/b&gt;&lt;b&gt;ها: &lt;/b&gt;&lt;/span&gt;تعدادپنج نمونه دایره ای شکل به قطر ۶ میلیمتروضخامت ۱ میلیمترازنمونه سمانهای Panavia F2.0 ، Choice2 ،گلاسیونومر GC ،زینک فسفات Hoffmann&amp;rsquo;s ،زینک پلیکربوکسیلات Hoffmann&amp;rsquo;s ،گلاسیونومرآریادنت،زینک فسفات آریادنت وزینک پلی کربوکسیلات آریادنت تهیه شد. رادیواپاسیته هرکدام ازنمونه ها به همراه Stepwedge آلومینیوم ی به وسیله یرادیوگرافی دیجیتالتی اندازه گیری شد . میانگین رادیوپاسیته اندازه گیری شده در ۵ ناحیه منظور شد که بوسلیه نرم افزار DFW و گیرنده PSP محاسبه شد.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;direction: rtl; text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;یافته ها: &lt;/b&gt;&lt;/span&gt;بین مقادیرمیانگین رادیواپاسیته سمانهای مورد مطالعه اختلاف معنی داری بدست آمد&lt;font color=&quot;#000000&quot;&gt;(0.001&lt;font style=&quot;BACKGROUND-COLOR: #ffffff&quot;&gt;&amp;ge;&lt;/font&gt;&lt;/font&gt;&lt;font style=&quot;BACKGROUND-COLOR: #ffffff&quot;&gt;&lt;font color=&quot;#000000&quot;&gt;P)&lt;/font&gt; بیشترین مقداررادیواپاسیته مربوط به زینک فسفات آریادنت بامیانگین وانحراف معیار &lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;font style=&quot;BACKGROUND-COLOR: #ffffff&quot;&gt;۰/&lt;/font&gt;&lt;/span&gt;۵۵&amp;plusmn;۷/۷ میلیمترآلومینیوم بدست آمد.همچنین کمترین مقدارمیانگین رادیواپاسیته مربوط به سمان گلاس آریادنت بامیانگین۰/۳۱&amp;plusmn;۸۲ /۰میلیمترآلومینیوم بدست آمد . &lt;/font&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;نتیجه گیری&lt;/b&gt;: &lt;/span&gt;تمام سمانهای موردمطالعه به جزسمان گلاسیونومرآریادنت مقداررادیواپاسیته برابریا بیشترازاستاندارد (ISO 4049:2000(E) راازخودنشان دادند. ومیتوان به عنوان سمان قابل قبول درسمان کردن رستوریشنهاازآنهااستفاده نمود.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Introduction: &lt;/b&gt;&lt;/span&gt;Radiopacity is a necessary property for luting cements . The aim of this study was to investigate the radiopacity of some luting dental cements used in prosthetic dentistry.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Methods: &lt;/b&gt;&lt;/span&gt;Five disclike samples of each material (6 x 1 mm) were prepared from panavia F2.0(Pa), Chioce2 (Ch.2), Glass ionomer GC (GI GC), zinc phosphate Hoffmann&amp;rsquo;s (ZP hof), zinc polycarboxylate Hoffmann&amp;rsquo;s (ZPC hof), Glass ionomer ariadent( GI ari), zinc phosphate ariadent(ZP ari) and zinc polycarboxylate ariadent (ZPC ari). The radiopacity of each material along with aluminium step wedge were measured from radiographic images using a digital radiography. The average measured radiopacities from five areas were taken into account, which were measured by Digora for windows (DFW) software using a PSP digital sensor.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Results: &lt;/b&gt;&lt;/span&gt;There was a significant difference between radiopacity value of all luting materials (P&amp;le;0.001). ZP ari had the highest radiopacity with 7.7&amp;plusmn;0.55 mm aluminium. The Glass ionomer ariadent ari dent showed the lowest radiopacity value with 0.82&amp;plusmn;0.31 mm aluminium.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Conclusion: &lt;/b&gt;&lt;/span&gt;All dental cements showed radiopacity values equivalent to or greater than the ISO 4049:2000(E)standard except ariadent Glass ionomer and this could be considered suitable for use in restoration cementation.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>رادیواپاسیته,رادیوگرافی دیجیتال,مواد دندانی</keyword_fa>
	<keyword>Radiopacity, Digital radiography, Dental material</keyword>
	<start_page>28</start_page>
	<end_page>34</end_page>
	<web_url>http://cjdr.ir/browse.php?a_code=A-10-124-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Abdolhamid</first_name>
	<middle_name></middle_name>
	<last_name>Alhavaz</last_name>
	<suffix></suffix>
	<first_name_fa>عبدالحمید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آل هوز</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ahalhavaz@yahoo.com</email>
	<code>100319475328460015611</code>
	<orcid>100319475328460015611</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>,Dental Materials Research Center, Department of Prosthodontics, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات مواد دندانی، گروه پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Sina</first_name>
	<middle_name></middle_name>
	<last_name>Haghanifar</last_name>
	<suffix></suffix>
	<first_name_fa>سینا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حقانی فر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Dr_haghanifar@gmail.com</email>
	<code>100319475328460015612</code>
	<orcid>100319475328460015612</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Oral &amp; Maxillofacial Radiology, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،گروه رادیولوژی دهان،فک وصورت، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Yashar</first_name>
	<middle_name></middle_name>
	<last_name>Vakili</last_name>
	<suffix></suffix>
	<first_name_fa>یاشار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>وکیلی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>yashi_dent85@yahoo.com</email>
	<code>100319475328460015613</code>
	<orcid>100319475328460015613</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,none</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Arash</first_name>
	<middle_name></middle_name>
	<last_name>Poorsattar-Bejehmir</last_name>
	<suffix></suffix>
	<first_name_fa>آرش</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پورستار بجه میر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>arashpoorsattar@yahoo.com</email>
	<code>100319475328460015614</code>
	<orcid>100319475328460015614</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Dental Materials Research Center, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات مواد دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
