<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Caspian Journal Of Dental Research</title>
<title_fa>مجله تحقيقات دندانپزشكي كاسپين</title_fa>
<short_title>Caspian J Dent Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://cjdr.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-9890</journal_id_issn>
<journal_id_issn_online>2322-2395</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/cjdr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>2</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>دقت اندازه گیری خطی عمودی مندیبل در تصاویر پانورامیک و توموگرافی</title_fa>
	<title>Accuracy of mandibular vertical linear measurement in panoramic and tomography images</title>
	<subject_fa>رادیولوژی دهان، فک و صورت </subject_fa>
	<subject>Oral &amp; Maxillofacial  Radiology</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Paper</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;مقدمه: &lt;/strong&gt;&lt;/span&gt;دقت اندازه گیری فک برای جراحی یا نصب ایمپلنت ها حائز اهمیت می باشد. رادیوگرافی های قبل از ایمپلنت بخش مهمی از ارزیابی های بالینی قبل از جراحی ایمپلنت به حساب می آیند. برای انتخاب محل باید ساختارهای آناتومی مهم مثل سوراخ منتال، کانال آلوئولار تحتانی، حفره بینی و سینوس ماگزیلا را در نظر بگیریم. شناخت دقت و اندازه گیری تکنیک های رادیوگرافی دارای اهمیت است. هدف این تحقیق، مقایسه اندازه گیری خطی عمودی مندیبولار در تصاویر پانورامیک و توموگرافی می باشد.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;مواد و روش ها: &lt;/strong&gt;&lt;/span&gt;سه فرم مندیبل از جمجمه خشک شده فرد بزرگسال در این تحقیق مورد استفاده قرار گرفتند (مثلثی، مربع و بیضی). برای هر مندیبل، استنت جراحی با استفاده از آکریل شفاف استاندارد طلایی ساخته شد. یک لوله نازک در استنت ها در سه ناحیه قرار داده شد (اینسیزور، پریمولار و مولار) تاگاتا پرکا را تنظیم کنیم. سپس نمای پانورامیک و توموگرافی معمولی بدست آمد. چهار رادیولوژیست دهان و ماگزیلوفیشال بعد عمودی در توموگرافی پانورامیک و معمولی را اندازه گرفتند. در پایان هرمندیبل در بخش های مشخص شده برش داده شد و به وسیله یک اندازه گیری دیجیتال (استاندارد طلایی) اندازه گیری شد و با توموگرافی معمولی و نمای پانورامیک مقایسه شد. داده های حاصل با استفاده از نرم افزار SPSS نسخه 18 و t تست و ضریب همبستگی پیرسون و آزمون من-ویتنی غیرپارامتریک تجزیه وتحلیل شدند.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;یافته ها: &lt;/strong&gt;&lt;/span&gt;نتایج میانگین اختلافات بین میانگین مقادیر بعد پانورامیک و بعد عمودی خطی استاندارد طلایی در نواحی پریمولار و مولار بالای 1mm بوده است و در ناحیه اینسیزور بالای 2mm بوده است. میانگین اختلافات بین اندازه گیری های توموگرافی معمولی و استاندارد طلایی در هر سه ناحیه 1mm بوده است.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;نتیجه گیری: &lt;/strong&gt;&lt;/span&gt;اندازه گیری خطی بعد عمودی در توموگرافی معمولی دقیق تر از پانورامیک بود. استفاده از یک لبه ایمنی 2mm در ارزیابی جایگاه های ایمپلنت توصیه می شود. در ناحیه اینسیزور، شیوه های دیگر رادیوگرافی مثل CBCT پیشنهاد می شود.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Introduction: &lt;/b&gt;&lt;/span&gt;The measurement precision of jaw is important for surgery or installing implants. Preimplant radiographs are important part of clinical evaluations before implant surgery. For choosing location, we should consider the important anatomical structures like mental foramen, inferior alveolar canal, nasal cavity and maxillary sinus.It is important to know the measurement accuracy of radiographic techniques. The purpose of this study was to compare mandibular vertical linear measurement in panoramic and tomography images.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Methods: &lt;/b&gt;&lt;/span&gt;Three forms of mandible from dry adult human skulls were used in this study (triangle, square and ellipse). For each mandible, surgical stent was made using transparent with gold standard.acryl. A thin tube was placed in the stents in three regions (incisors, premolars and molars) to set gutta-percha. Then, the panoramic view and conventional tomography were obtained. Four oral and maxillofacial radiologists measured the vertical dimension in panoramic and conventional tomography. Finally, each mandible was sectioned in the marked sections and was measured by a digital caliper (gold standard) and compared with conventional tomography and panoramic view .The obtained data was analyzed using SPSS18 software and student t-test, Pearson correlation coefficient and non parametric Mann-Whitney Test.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Results: &lt;/b&gt;&lt;/span&gt;The mean difference between the panoramic and gold standard linear vertical dimension values in premolar and molar regions was above 1mm and above 2mm in incisor region. The mean difference between conventional tomography and gold standard measurements in all three regions was 1mm.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;b&gt;Conclusions: &lt;/b&gt;&lt;/span&gt;The linear measurement of vertical dimension in conventional tomography was more precise than panoramic. The use of a 2.0 mm safety margin in the evaluation of implant sites was recommended.In incisor area, the other radiography methods like CBCT was suggested.&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>ایمبلنت, پانورامیک, رادیوگرافی, توموگرافی معمولی</keyword_fa>
	<keyword>Implant, Panoramic, Radiography, Conventional tomography</keyword>
	<start_page>25</start_page>
	<end_page>31</end_page>
	<web_url>http://cjdr.ir/browse.php?a_code=A-10-87-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ehsan</first_name>
	<middle_name></middle_name>
	<last_name>Moudi</last_name>
	<suffix></suffix>
	<first_name_fa>احسان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>موعودی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ehsan.moudi@gmail.com</email>
	<code>100319475328460015952</code>
	<orcid>100319475328460015952</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Oral &amp; Maxillofacial Radiology, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،گروه رادیولوژی دهان،فک و صورت، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Sina</first_name>
	<middle_name></middle_name>
	<last_name>Haghanifar</last_name>
	<suffix></suffix>
	<first_name_fa>سینا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حقانی فر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dr_haghanifar@yahoo.com</email>
	<code>100319475328460015953</code>
	<orcid>100319475328460015953</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Oral &amp; Maxillofacial Radiology, Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،گروه رادیولوژی دهان،فک و صورت، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Hoora</first_name>
	<middle_name></middle_name>
	<last_name>Hadian</last_name>
	<suffix></suffix>
	<first_name_fa>حورا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هادیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>h.haadian@yahoo.com</email>
	<code>100319475328460015954</code>
	<orcid>100319475328460015954</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>,Department of Oral &amp; Maxillofacial Radiology, Shahid Beheshti University of Medical Sciences, Tehran-Iran.</affiliation>
	<affiliation_fa>،گروه رادیولوژی دهان،فک و صورت، دانشگاه علوم پزشکی شهید بهشتی ،تهران-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali</first_name>
	<middle_name></middle_name>
	<last_name>Bijani</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیژنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>alibijani@yahoo.com</email>
	<code>100319475328460015955</code>
	<orcid>100319475328460015955</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Non-Communicable Pediatric Diseases Research Center, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات بیماری های غیرواگیر کودکان، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Mirmahmood</first_name>
	<middle_name></middle_name>
	<last_name>Safinia</last_name>
	<suffix></suffix>
	<first_name_fa>میرمحمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صفی نیا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mmsafinia@yahoo.com</email>
	<code>100319475328460015956</code>
	<orcid>100319475328460015956</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,none</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Nika</first_name>
	<middle_name></middle_name>
	<last_name>Bahemmat</last_name>
	<suffix></suffix>
	<first_name_fa>نیکا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>با همت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nika_bahemmatcc@yahoo.com</email>
	<code>100319475328460015957</code>
	<orcid>100319475328460015957</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Oral &amp; Maxillofacial Radiology, Shahid Beheshti University of Medical Sciences, Tehran-Iran.</affiliation>
	<affiliation_fa>،گروه رادیولوژی دهان،فک و صورت، دانشگاه علوم پزشکی شهید بهشتی،تهران-ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
