<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Caspian Journal Of Dental Research</title>
<title_fa>مجله تحقيقات دندانپزشكي كاسپين</title_fa>
<short_title>Caspian J Dent Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://cjdr.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-9890</journal_id_issn>
<journal_id_issn_online>2322-2395</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/cjdr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>دقت ابعادی روش مولد آلژیناتی در نسخه برداری از کست های گچی استون</title_fa>
	<title>Dimensional accuracy of alginate mold method on duplication of stone casts</title>
	<subject_fa>پروتزهای دندانی</subject_fa>
	<subject>Prosthodontics</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Paper</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;مقدمه&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;:&lt;/span&gt; نسخه برداری دقیق کست ها، برای به دست آوردن یک پروتز مناسب و دارای تطابق ضروری است. آلژینات ماده ای ارزان بوده در اکثر مطب ها در دسترس است. هدف این مطالعه بررسی دقت کست های نسخه برداری شده حاصل از قالبگیری با روش مولد آلژیناتی&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;بود&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;b&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;مواد و روش ها:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&amp;nbsp;&lt;/span&gt;در این مطالعه آزمایشگاهی&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&amp;nbsp;ابتدا با استفاده از تری فلزی و سیلیکون تراکمی از یک دنتیک مگزیلا ۶۰ قالب اصلی تهیه گردید. قالب ها با گچ استون ریخته شده، ابعاد آن ها با کولیس دیجیتال با دقت&amp;nbsp; 0.01&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;mm&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&amp;nbsp;اندازه گیری شد. سپس کست ها در کف فلاسک ثابت شده، فلاسک با آلژیناتی که میزان آب سرد ترکیب آن ۲ برابر دستور کارخانه بود پر شد. قالب های حاصله&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt; بلافاصله ریخته و اندازه گیری ها تکرار شد&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;سپس نتایج در نرم افزار &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;SPSS&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;نسخه ۲۶ و با آزمون&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;MANOVA &lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;و شاخص&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&amp;nbsp;ICC &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;بررسی شدند (&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;p&lt;0.05&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;). &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;یافته ها&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;:&lt;/span&gt; بررسی های آماری نشان داد تغییرات ابعادی کست های نسخه برداری شده نسبت به کست های اصلی نظیر آن معنادار نبود&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;P=0.90&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;).&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;همچنین قالب های نسخه برداری شده کوچکتر شده بودند. تغییرات ابعادی در بعد عرضی بیشتر از بعد قدامی&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;خلفی بود.&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;نتیجه&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt; &lt;b&gt;گیری:&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&amp;nbsp;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;نتایج مطالعه نشان داد قالب های نسخه دوم آلژیناتی که با روش مولد آلژیناتی گرفته شده باشند، اگر بلافاصله ریخته شوند از دقت ابعادی قابل قبولی برخوردارند. با توجه به ارزان بودن آلژینات، می توان از این روش با صرف زمان کم در مطب استفاده کرد و هزینه های لابراتواری و مواد قالبگیری گرانقیمت را کاهش داد&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:&quot;B Nazanin&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:18.0pt&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:&quot;B Nazanin&quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;Introduction:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt; Accurate duplication of casts is necessary to fabricate a proper prosthetic appliance with good adaptation. Alginate is an inexpensive impression material and is available in most dental offices.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;line-height:200%&quot;&gt; &lt;span style=&quot;background:white&quot;&gt;The aim of the present study was to evaluate the accuracy of the casts duplicated using alginate impression mold.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;Materials &amp; Methods:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt; In this in vitro study, at first, a metallic tray and condensational silicone impression material were used to prepare 60 master impressions of a maxillary dental model. The impressions were poured using stone gypsum, and their dimensions were measured via a digital &lt;span style=&quot;color:#0d0d0d&quot;&gt;Vernier caliper with accuracy of&lt;/span&gt; 0.01 mm. Then, the casts were fixed on the floor of a flask filled with alginate with two folds volume of cold water recommended by the manufacturer. The resulting impressions were immediately poured, and the measurements were repeated. The data were analyzed with SPSS 26 using MANOVA and ICC index (p&lt;0.05). &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt; &lt;/span&gt;Statistical analyses showed that dimensional changes of the duplicated casts were not significant relative to the master casts (P=0.90). In addition, insignificantly, the duplicate casts were smaller than the master casts and the dimensional changes in the transverse dimension were more than those in the anteroposterior dimension. &amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;b&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;span style=&quot;background:white&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt; The results indicated that alginate duplicate impressions taken using the alginate molding technique had good dimensional accuracy when they were poured immediately. Since alginate is inexpensive, this technique can be used in the dental office by saving time to decrease laboratory costs and avoid using expensive impression materials.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;text-justify:kashida&quot;&gt;&lt;span style=&quot;text-kashida:0%&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:Calibri,sans-serif&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:12.0pt&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>کلسیم سولفات, امکانات دندانی, مدل های دندانی</keyword_fa>
	<keyword>Calcium Sulfate, Dental Facilities, Dental Models</keyword>
	<start_page>91</start_page>
	<end_page>97</end_page>
	<web_url>http://cjdr.ir/browse.php?a_code=A-10-480-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Neda</first_name>
	<middle_name></middle_name>
	<last_name>Naderi Geisour</last_name>
	<suffix></suffix>
	<first_name_fa>ندا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نادری گیسور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nadneda74@gmail.com</email>
	<code>100319475328460018301</code>
	<orcid>100319475328460018301</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran</affiliation>
	<affiliation_fa>، دانشکده دندانپزشکی، دانشگاه علوم پزشکی زنجان، زنجان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Hafez</first_name>
	<middle_name></middle_name>
	<last_name>Ariamanesh</last_name>
	<suffix></suffix>
	<first_name_fa>حافظ</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آریامنش</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hafezariamanesh@gmail.com</email>
	<code>100319475328460018302</code>
	<orcid>100319475328460018302</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Prosthodontics, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran.</affiliation>
	<affiliation_fa>،گروه پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی زنجان، زنجان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Mostafa</first_name>
	<middle_name></middle_name>
	<last_name>Sheikhi</last_name>
	<suffix></suffix>
	<first_name_fa>مصطفی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شیخی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mostafasheikhi9045@gmail.com</email>
	<code>100319475328460018303</code>
	<orcid>100319475328460018303</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>,Department of Orthodontics, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran.</affiliation>
	<affiliation_fa>،گروه ارتودنسی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی زنجان، زنجان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Sajjad</first_name>
	<middle_name></middle_name>
	<last_name>Pezeshki</last_name>
	<suffix></suffix>
	<first_name_fa>سجاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پزشکی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sajjad.pezeshki@gmail.com</email>
	<code>100319475328460018304</code>
	<orcid>100319475328460018304</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Prosthodontics, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran.</affiliation>
	<affiliation_fa>،گروه پروتزهای دندانی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی زنجان، زنجان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Mehdi</first_name>
	<middle_name></middle_name>
	<last_name>Mohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohammadimohammadmehdi95@gmail.com</email>
	<code>100319475328460018305</code>
	<orcid>100319475328460018305</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran.</affiliation>
	<affiliation_fa>، دانشکده دندانپزشکی، دانشگاه علوم پزشکی زنجان، زنجان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
