<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Caspian Journal Of Dental Research</title>
<title_fa>مجله تحقيقات دندانپزشكي كاسپين</title_fa>
<short_title>Caspian J Dent Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://cjdr.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-9890</journal_id_issn>
<journal_id_issn_online>2322-2395</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/cjdr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1400</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2021</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>10</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثر درمانهای سطحی مختلف بر میزان استحکام باند ریزکششی دو نوع زیرساخت کامپوزیتی با سرامیک توسط سمان رزینی</title_fa>
	<title>Effect of different surface treatments on microtensile bond strength of two types of composite substructures with ceramic by resin cements</title>
	<subject_fa>دندانپزشکی ترمیمی</subject_fa>
	<subject>Restorative Dentistry</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Paper</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt;&lt;/span&gt; هدف از این مطالعه بررسی تأثیر درمانهای سطحی مختلف بر استحکام باند ریزکششی دو نوع زیرساخت کامپوزیتی با سرامیک&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;II&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;Mark&amp;nbsp;&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;Vita&lt;/span&gt; توسط سمان رزینی بود.&lt;br&gt;
&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;مواد و روش ها:&lt;/strong&gt;&lt;/span&gt; تعداد ۶۴ نمونه به میزان مساوی از دو نوع کامپوزیت دوآل کیور &lt;span dir=&quot;LTR&quot;&gt;Core.it&lt;/span&gt; و &lt;span dir=&quot;LTR&quot;&gt;Build-it&lt;/span&gt;&lt;strong&gt; &lt;/strong&gt;ساخته و توسط نور &lt;span dir=&quot;LTR&quot;&gt;LED&lt;/span&gt; کیور شد. نمونه&amp;shy; ها در هر گروه بطور تصافی به ۴ زیرگروه تقسیم و با یکی از روشهای اسید فلوریدریک ۱۰%، لیزر&amp;nbsp; Er:YAG، &lt;span dir=&quot;LTR&quot;&gt;abrasion&amp;nbsp;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;air&amp;nbsp;&lt;/span&gt;&amp;nbsp; تحت درمان سطحی قرار گرفتند (۸ نمونه). یک گروه نیز به عنوان کنترل بدون درمان سطحی باقی ماند. سپس نمونه&amp;shy; های هر زیرگروه توسط دو نوع سمان رزینی &lt;span dir=&quot;LTR&quot;&gt;Duo-Link&lt;/span&gt; و &amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;Panavia F 2.0&lt;/span&gt;به بلوکهای سرامیکی &lt;span dir=&quot;LTR&quot;&gt;Vita Mark II CAD/CAM&lt;/span&gt; باند شدند (۴ نمونه). نمونه &amp;shy;های حاصل به تعداد ۲۵۰۰ سیکل بین دو دمای ۵ و ۵۵ درجه سانتی&amp;shy;گراد مورد ترموسایکلینگ قرار گرفتند و توسط دیسک برش با سرعت پایین جهت حصول ۵ استوانه با سطح مقطع ۱ میلی&amp;shy;متر مربع برش زده شدند. آزمون استحکام باند ریزکششی با سرعت &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;RTL&quot;&gt;&lt;span style=&quot;font-family:Tahoma,sans-serif;&quot;&gt;&lt;span style=&quot;font-size:9.0pt;&quot;&gt;۰/۵&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;میلی&amp;shy;متر بر دقیقه توسط ماشین تست یونیورسال انجام پذیرفت و الگوی شکست توسط استریومیکروسکوپ مورد بررسی قرار گرفت. تفاوتهای آماری بین گروهها با استفاده از آزمونهای &lt;span dir=&quot;LTR&quot;&gt;ANOVA&lt;/span&gt; یک طرفه و&amp;nbsp;آزمونهای مقایسه چندگانه &lt;span dir=&quot;LTR&quot;&gt;Tukey&lt;/span&gt; تعیین شد.&lt;br&gt;
&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;یافته ها:&lt;/strong&gt;&lt;/span&gt; بیشنرین میزان استحکام باند کششی بین ۱۶ گروه مورد مطالعه در گروه با زیرساخت &lt;span dir=&quot;LTR&quot;&gt;Core.it&lt;/span&gt; بدون درمان سطحی و سمان &lt;span dir=&quot;LTR&quot;&gt;Duo-Link&lt;/span&gt; و در رتبه دوم با زیرساخت &lt;span dir=&quot;LTR&quot;&gt;Build-it&lt;/span&gt; بدون درمان&amp;nbsp; سطحی و سمان &lt;span dir=&quot;LTR&quot;&gt;Panavia&lt;/span&gt; بود. بیشترین الگوی شکست مشاهده شده در تمامی گروههای مورد مطالعه، شکست کوهزیو در سمان رزینی بود&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;(&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;P value&lt;0.05&lt;/span&gt;&lt;/span&gt;)&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;.&lt;br&gt;
&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;نتیجه &amp;shy;گیری:&lt;/strong&gt;&lt;/span&gt; با توجه به این مطالعه، درمانهای سطحی&amp;nbsp; زیر ساخت توسط اسید فلوریدریک ، لیزرو &amp;nbsp;هواسایی باعث کاهش استحکام باند آن با سرامیک شد و لذا استفاده از این درمانها پیشنهاد نمیگردد.&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:Times New Roman,serif;&quot;&gt;&lt;span style=&quot;font-size:12.0pt;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;Introduction&lt;/strong&gt;:&lt;/span&gt; The aim of this study was to investigate the effect of different surface treatments on the microtensile bond strength (&amp;micro;TBS) of two types of composite substructures with Vita Mark II ceramics by resin cement.&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;Materials &amp; Methods&lt;/strong&gt;: &lt;/span&gt;Sixty-four substructure specimens were molded from two dual-cure composites Core.it and Build-it, equally, and cured by LED light. The specimens of each group were randomly divided into 4 subgroups (n=8) treated by one of HF acid 10%, air abrasion, Er: YAG laser, and one group without any treatment (control group), and then the specimens of each group were bonded to Vita Mark II CAD/CAM ceramic blocks using two Duo-Link and Panavia F 2.0 resin (n=4 and 20 slice in any group). Each final specimen was thermocycled between 5 &amp;deg;C and 55 &amp;deg;C for 2500 cycles and then cut by a slow speed saw to obtain 5 sticks with cross-section dimensions of about 1&amp;times;1 mm&amp;sup2;. The &amp;micro;TBS test was done at a speed of 0.5 mm/min by Universal Testing Machine. The fracture pattern was then determined using a stereomicroscope. Statistical differences between groups were determined by one-way ANOVA using Tukey&amp;#39;s multiple comparison tests.&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;Results&lt;/strong&gt;:&lt;/span&gt; Among all 16 groups, the highest &amp;micro;TBS was observed in the group with Core.it substructure composite and Duo-link resin cement without any surface treatment and after that in the second step in build-it substructure composite group and Panavia resin cement without surface treatment. The most common fracture pattern in all groups was cohesive in resin cement (P value&lt;0.05).&lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;color:#000099;&quot;&gt;&lt;strong&gt;Conclusion&lt;/strong&gt;:&lt;/span&gt; According to this study, composite substructure surface treatment by hydrofloridric acid, laser and air abrasion reduced &amp;micro;TBS between substructure- ceramic and so &amp;nbsp;is not recommended.&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>سمان رزینی, سرامیک, Vita Mark II</keyword_fa>
	<keyword>Resin Cements, Ceramics, Vita Mark II</keyword>
	<start_page>38</start_page>
	<end_page>44</end_page>
	<web_url>http://cjdr.ir/browse.php?a_code=A-10-34-4&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Negin</first_name>
	<middle_name></middle_name>
	<last_name>Tabari</last_name>
	<suffix></suffix>
	<first_name_fa>نگین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طبری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ntabari@yahoo.com</email>
	<code>100319475328460016907</code>
	<orcid>100319475328460016907</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>------------------------------------------------------------</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyedkamal</first_name>
	<middle_name></middle_name>
	<last_name>Seyedmajidi</last_name>
	<suffix></suffix>
	<first_name_fa>سیدکمال</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سیدمجیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sksmajidi86@yahoo.com</email>
	<code>100319475328460016908</code>
	<orcid>100319475328460016908</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Department of Materials and Industrial, Babol Noshirvani University of Technology, Babol, Iran.</affiliation>
	<affiliation_fa>، دانشکده مهندسی مواد و صنایع، دانشگاه صنعتی نوشیروانی بابل، بابل، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Toloo</first_name>
	<middle_name></middle_name>
	<last_name>Jafari</last_name>
	<suffix></suffix>
	<first_name_fa>طلوع</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>tolooj@yahoo.com</email>
	<code>100319475328460016909</code>
	<orcid>100319475328460016909</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>------------------------------------------------------------</affiliation_fa>
	 </author>


	<author>
	<first_name>Soraya</first_name>
	<middle_name></middle_name>
	<last_name>Khafri</last_name>
	<suffix></suffix>
	<first_name_fa>ثریا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>khafri@yahoo.com</email>
	<code>100319475328460016910</code>
	<orcid>100319475328460016910</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Dental Materials Research Center, Health Reasearch Institute, Babol University of Medical Sciences, Babol, Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات مواد دندانی، پژوهشکده سلامت، دانشگاه علوم پزشکی بابل، بابل، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Homayoon</first_name>
	<middle_name></middle_name>
	<last_name>Alaghehmand</last_name>
	<suffix></suffix>
	<first_name_fa>همایون</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>علاقه مند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>halagheh@yahoo.com</email>
	<code>100319475328460016911</code>
	<orcid>100319475328460016911</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>,Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran.</affiliation>
	<affiliation_fa>، مرکز تحقیقات مواد دندانی، پژوهشکده سلامت، دانشگاه علوم پزشکی بابل، بابل، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
