<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Caspian Journal Of Dental Research</title>
<title_fa>مجله تحقيقات دندانپزشكي كاسپين</title_fa>
<short_title>Caspian J Dent Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://cjdr.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-9890</journal_id_issn>
<journal_id_issn_online>2322-2395</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/cjdr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1394</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2015</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>4</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه ی استحکام باند برشی براکت های فلزیSteel  Stainless باند شده توسط سه نوع ادهزیو لایت کیور</title_fa>
	<title>Comparison of shear bond strength of stainless steel brackets bonded with three light- cured adhesives</title>
	<subject_fa>ارتودنتیکس</subject_fa>
	<subject>Orthodontics</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Paper</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&amp;nbsp;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;strong&gt;مقدمه&lt;/strong&gt;&lt;strong&gt;: &lt;/strong&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;فرآیند اتصال براکت به مینا یک مسئله مهم در تحقیقات ارتودنسی است. هدف از این مطالعه مقایسه استحکام باند برشی براکتهای فلزی stainless steel چسبانده شده توسط ادهزیوهای light bond ، transbond xt و Z250 با یکدیگر می باشد.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&amp;nbsp;&lt;strong&gt;م&lt;span style=&quot;color:#000080;&quot;&gt;واد و روش ها: &lt;/span&gt;&lt;/strong&gt;در این مطالعه ٦٠ دندان پرمولر کشیده شده ی انسانی، بصورت تصادفی به ٣ گروه مساوی تقسیم شدند: همه دندان ها با ژل اسید فسفریک ٣٧% اچ شدند. در گروه اول براکت ها با ادهزیو Transbond XT ، در گروه دوم با ادهزیو light bond و در گروه سوم با کامپوزیت Z250(filtek) بر روی دندانها قرار گرفت و با ortholux xt به مدت ۴۰ ثانیه کیور گردید. ٢٤ ساعت پس از انجام ترموسایکلینگ، استحکام باند برشی براکت ها توسط دستگاه Universal testing machine (Instron) اندازه گیری شد. بعد از دی باند ایندکس رزین باقی مانده (ARI) با استریو میکروسکوپ تعیین گردید. یافته ها توسط آنالیز واریانس ANOVA و Chi-square ارزیابی گردیدند.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;یافته ها: &lt;/strong&gt;&lt;/span&gt;میانگین استحکام باند برشی برحسب مگاپاسکال برای گروه اول ۲/۲۵ &amp;plusmn; ۲۸/۹،گروه دوم ۱/۹۸ &amp;plusmn; ۲۵/۰۶ و در گروه سوم ۲/۵۷ &amp;plusmn; ۲۶/۸ بود. استحکام باند برشی بین گروه ها اختلاف معنی داری نداشت (P=0.2) و هر سه ادهزیو SBS کلینیکی قابل قبولی داشتند. سنجش ARI در بین گروه ها اختلاف معنی داری را نشان نداد (P&gt;0.05).&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;نتیجه گیری: &lt;/strong&gt;&lt;/span&gt;این تحقیق نشان داد که Z250 جهت باند براکت های ارتودنسی می تواند همانند light bond و transbond xt مورد استفاده قرار گیرد و تفاوت معناداری از نظر ARI و SBS با آنها ندارد.&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Introduction: &lt;/strong&gt;&lt;/span&gt;The bonding process of the brackets to enamel has been a critical issue in orthodontic research. The purpose of this study was to evaluate the shear bond strength of 3 light-cured adhesives (transbond XT, Z250, light bond).&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Materials &amp;Methods: &lt;/strong&gt;&lt;/span&gt;In this study sixty extracted human premolars were collected and randomly divided into 3 test groups. All teeth were etched by 37% phosphoric acid. In first group brackets were bonded by Transbond XT adhesive, in group two brackets were bonded by Light bond adhesive and in third group were bonded by filtek Z250 composite. All of them were cured with Ortholux xt for 40 seconds.24 hours after thermocycling, Shear Bond Strength (SBS) values of these brackets were recorded using a Universal Testing Machine. Adhesive Remnant Index (ARI) scores were determined after the failure of the brackets, using Stereo Microscope the data were analyzed using ANOVA and Chi-square tests.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Results: &lt;/strong&gt;&lt;/span&gt;Mean shear bond strength of Transbond XT, light bond and Z250 were 28.9&amp;plusmn;2.25 MPa, 25.06&amp;plusmn;1.98 MPa and 26.8&amp;plusmn;2.57 MPa, respectively. No significant difference was observed in the SBS among the groups and a clinically acceptable SBS was found for the three adhesives. ARI scores were not significantly different between the various groups (P&gt;0.05).&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Conclusion: &lt;/strong&gt;&lt;/span&gt;This study showed that the Z250 can be used as light bond and transbond xt to bond orthodontic brackets and ARI and SBS scores were not significantly different.&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>ادهزیو, استحکام برشی, سمان های رزینی, کامپوزیت های رزینی</keyword_fa>
	<keyword>Adhesives, Shear strength, Resin cements, Composite resins</keyword>
	<start_page>27</start_page>
	<end_page>32</end_page>
	<web_url>http://cjdr.ir/browse.php?a_code=A-10-135-2&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Zahra</first_name>
	<middle_name></middle_name>
	<last_name>Minaei Basharik</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مینایی باشریک</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>z.minaei@yahoo.com</email>
	<code>100319475328460015578</code>
	<orcid>100319475328460015578</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Faculty of Dentistry, Babol  University of Medical Sciences, Babol, Iran.</affiliation>
	<affiliation_fa>،دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل،ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Manouchehr</first_name>
	<middle_name></middle_name>
	<last_name>Rahmati Kamel</last_name>
	<suffix></suffix>
	<first_name_fa>منوچهر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رحمتی کامل</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_ramati_kamel@yahoo.com</email>
	<code>100319475328460015579</code>
	<orcid>100319475328460015579</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Dental Materials Research Center, Department of Orthodontics, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات مواد دندانی، گروه ارتودنسی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل،ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Pouyan</first_name>
	<middle_name></middle_name>
	<last_name>Amini Shakib</last_name>
	<suffix></suffix>
	<first_name_fa>پویان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امینی شکیب</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>pouyanshakib@yahoo.com</email>
	<code>100319475328460015580</code>
	<orcid>100319475328460015580</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Oral and Maxillofacial Pathology Department, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>،گروه پاتولوژی دهان،فک و صورت، دانشکده دندانپزشکی، دانشگاه علوم پزشکی تهران،تهران،ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Maysam</first_name>
	<middle_name></middle_name>
	<last_name>Mirzaie</last_name>
	<suffix></suffix>
	<first_name_fa>میثم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>maysam2352@gmail.com</email>
	<code>100319475328460015581</code>
	<orcid>100319475328460015581</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>,Dental Materials Research Center, Department of Orthodontics, Faculty of Dentistry, Babol University of Medical Sciences, Babol, Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات مواد دندانی، گروه ارتودنسی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل،ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Ali</first_name>
	<middle_name></middle_name>
	<last_name>Bijani</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیژنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>alibijani@yahoo.com</email>
	<code>100319475328460015582</code>
	<orcid>100319475328460015582</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Non-Communicable Pediatric Diseases Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran.</affiliation>
	<affiliation_fa>،مرکز تحقیقات بیماریهای غیرواگیر کودکان، پژوهشکده سلامت، دانشگاه علوم پزشکی بابل،بابل،ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
