<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Caspian Journal Of Dental Research</title>
<title_fa>مجله تحقيقات دندانپزشكي كاسپين</title_fa>
<short_title>Caspian J Dent Res</short_title>
<subject>Medical Sciences</subject>
<web_url>http://cjdr.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2251-9890</journal_id_issn>
<journal_id_issn_online>2322-2395</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22088/cjdr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa>تاثیر بلیچینگ بر میکروهاردنس کامپوزیت بابیس سایلوران</title_fa>
	<title>The effect of bleaching on microhardness of silorane-based composite resins</title>
	<subject_fa>دندانپزشکی ترمیمی</subject_fa>
	<subject>Restorative Dentistry</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Paper</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;&amp;nbsp;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;مقدمه &lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;: &lt;/strong&gt;&lt;/span&gt;درمانهای بلیچینگ ممکن است بر کیفیت سطح ترمیمهای کامپازیتی موجود در دهان اثر منفی داشته باشند. هدف این مطالعه تعیین اثر کارباماید پراکسید ۱۶% و ۳۵% بر ریزسختی کامپوزیتهای بابیس سایلوران در مقایسه با دو کامپوزیت بابیس متاکریلات می باشد.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&amp;nbsp;&lt;strong&gt;مواد و روش ها: &lt;/strong&gt;&lt;/span&gt;۱۸عدد دیسک کامپوزیتی با رنگ A3&lt;strong&gt; &lt;/strong&gt;از هر کدام از کامپازیت های (Filtek P90, Filtek Z350XT Enamel, Filtek Z250) و در مجموع ۵۴ عدد با استفاده از مولد استنلس استیل ساخته شدند. هر یک از کامپوزیتها بصورت تصادفی به ۳ گروه مختلف تقسیم شدند (n=6). یک گروه در آب مقطر به مدت ۲ هفته در دمای اتاق بعنوان نمونه های کنترل نگهداری شده و گروههای دیگر با کارباماید پراکساید ۱۶% (بلیچینگ در منزل)،۴ ساعت در روز به مدت ۱۴ روز و کارباماید پراکساید ۳۵% (بلیچینگ در مطب) یکبار ۴۰ دقیقه، مورد بلیچ قرار گرفتند. میزان ریزسختی نمونه ها قبل و بعد از بلیچینگ با استفاده از Vickers hardness testing machine اندازه گیری شد و داده ها با repeated measure ANOVA model آنالیز شدند.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;یافته ها: &lt;/strong&gt;&lt;/span&gt;ریزسختی اولیه P90 به طور معناداری کمتر از دو کامپوزیت دیگر بود. در مورد Z250 و Z350 درمان بلیچینگ باعث کاهش معنادار میزان ریزسختی نسبت به گروه کنترل شد (0.001&gt;p&lt;strong&gt;&amp;nbsp;&lt;/strong&gt;)&lt;strong&gt;، &lt;/strong&gt;اما در مورد P90 فقط ماده بلیچینگ مطب باعث کاهش معنادار میکروهاردنس شد (0.009=p) اثر بلیچینگ خانگی و مطب بر P90 متفاوت بود (۰/۰۱۵).&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;color:#000080;&quot;&gt;&lt;strong&gt;نتیجه گیری: &lt;/strong&gt;&lt;/span&gt;به دنبال درمان بلیچینگ ریزسختی کامپوزیتهای Z250 و Z350 به صورت معنی داری کاهش یافت ولی این کاهش به دنبال بلیچینگ در منزل در کامپوزیت P90 چندان قابل توجه نبوده است.&lt;/span&gt;&lt;/p&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Introduction: &lt;/strong&gt;&lt;/span&gt;Bleaching treatments may negatively affect the surface quality of composite restorations existing in the mouth. This study sought to assess the effect of 16% and 35% carbamide peroxide on microhardness of silorane-based versus two methacrylate-based composite resins.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Methods:&lt;/strong&gt; &lt;/span&gt;A total of 54 discs were fabricated from FiltekP90 (P90), FiltekZ350XT(Z350) Enamel and Filtek Z250(Z250) (n=18). Each group of composite specimens was randomly divided into 3 subgroups (n=6). The control subgroup was stored in distilled water for 2 weeks. Subgroup 2 specimens were bleached 4hours a day with 16% carbamide peroxide (Home bleaching) for 14 days. The 3&lt;sup&gt;rd&lt;/sup&gt; subgroup specimens were subjected to 35% carbamide peroxide (Office bleaching) applied once for 40 minutes. Microhardness of specimens was measured before and after bleaching by using Vickers hardness testing machine. Data were analyzed by using Repeated Measures ANOVA.&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt;&lt;/span&gt; Baseline microhardness of P90 was lower than that of the other two composite resins (p=0.001). Bleaching decreased the microhardness of Z250 and Z350 compared to the control group (p&lt;0.001). However, in P90, only the office bleaching material caused a reduction in microhardness (p=0.009). The effect of home and office bleaching on microhardness of P90 was different (p=0.015).&lt;/span&gt;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: tahoma;&quot;&gt;&lt;span style=&quot;color: rgb(0, 0, 128);&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; &lt;/span&gt;Bleaching treatments significantly decreased the microhardness of Z250 and Z350 composite resins but this reduction in P90 was not statistically significant after home bleaching.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>سختی, کامپوزیت رزین سایلوران, سفید کردن دندان,</keyword_fa>
	<keyword>Hardness, Silorane composite resin, Tooth bleaching,</keyword>
	<start_page>46</start_page>
	<end_page>53</end_page>
	<web_url>http://cjdr.ir/browse.php?a_code=A-10-78-1&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Sedighe Sadat</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi Kamangar</last_name>
	<suffix></suffix>
	<first_name_fa>صدیقه السادات</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی کمانگر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>smhk58950@gmail.com</email>
	<code>100319475328460015665</code>
	<orcid>100319475328460015665</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>,Operative Dentistry Department, Dental School, Tehran University of Medical Sciences, International campus, Tehran-Iran.</affiliation>
	<affiliation_fa>،گروه دندانپزشکی  ترمیمی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی تهران، واحد بین الملل،تهران-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Kiana</first_name>
	<middle_name></middle_name>
	<last_name>Kiakojoori</last_name>
	<suffix></suffix>
	<first_name_fa>کیانا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کیاکجوری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kkiakojoori@yahoo.com</email>
	<code>100319475328460015666</code>
	<orcid>100319475328460015666</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Faculty of Dentistry, Babol University of Medical Sciences, Babol-Iran.</affiliation>
	<affiliation_fa>،دانشکده دندانپزشکی، دانشگاه علوم پزشکی بابل،بابل-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Mansoore</first_name>
	<middle_name></middle_name>
	<last_name>Mirzaii</last_name>
	<suffix></suffix>
	<first_name_fa>منصور</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرزایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mir1335@yahoo.com</email>
	<code>100319475328460015667</code>
	<orcid>100319475328460015667</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Operative Dentistry Department, Dental School, Tehran University of Medical Sciences, Tehran- Iran.</affiliation>
	<affiliation_fa>،گروه دندانپزشکی  ترمیمی، دانشکده دندانپزشکی، دانشگاه علوم پزشکی تهران،تهران-ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Jalal</first_name>
	<middle_name></middle_name>
	<last_name>Purhashemi</last_name>
	<suffix></suffix>
	<first_name_fa>سید جلال</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>پور هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>pourhash@tums.ac.ir</email>
	<code>100319475328460015668</code>
	<orcid>100319475328460015668</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>,Pediatric Dentistry Department, Dental School, Tehran  University of Medical Sciences, International Campus, Tehran- Iran.</affiliation>
	<affiliation_fa>،گروه دندانپزشکی کودکان، دانشکده دندانپزشکی، دانشگاه علوم پزشکی تهران، واحد بین الملل،تهران-ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
