[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 7, Issue 1 ( March- 2018) ::
Caspian J Dent Res 2018, 7(1): 8-13 Back to browse issues page
Effect of different torques on dentinal crack formation following canal preparation using neoniti rotary system
Akam Saeidi , Mahmoodreza Hamidi , Azadeh Harandi , Mina Habibolahpour * , Hemmat Gholinia
,Student Research Committee, Babol University of Medical Sciences,Babol, IR Iran. , Mina.hbp@gmail.com
Abstract:   (2555 Views)
Introduction: The aim of this study was to determine the incidence of dentinal cracks in the  mesial root of maxillary molar during canal preparation using Neoniti system in different torque settings.
Materials &Methods: In this in-vitro study, 60 maxillary molars extracted for various reasons were selected. The teeth were divided into 4 groups: one group(n=15) without preparation was considered as a control group (unprepared control group), the other 3 groups prepared with rotary neoniti system: group with standard torque (1.5 N/CM2)(n=15), group with high torque (2N/CM2)(n=15), and group with low torque (1N /CM2)(n=15). After a canal preparation procedure, the teeth were horizontally sectioned at 3, 6 and 9 mm from the apex. All sections were examined for determining the presence of cracks using a stereomicroscope. Data were analyzed using chi-square test.
Results: There was no crack in the control group. The number of cracks was significantly higher in the high-torque group (80%) than standard- and low-torque groups (20%, 26.7%, respectively) (p<0.001). However, no significant difference was found between the standard-torque group and low-torque group (p<0.001).
Conclusion: According to this study result, to avoid crack formation in higher torques using motors with torque control option is suggested.
Keywords: Dentin, Root canal preparation, Torque
Full-Text [PDF 1068 kb]   (930 Downloads)    
Type of Study: Original Article | Subject: Endodontics
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Saeidi A, Hamidi M, Harandi A, Habibolahpour M, Gholinia H. Effect of different torques on dentinal crack formation following canal preparation using neoniti rotary system . Caspian J Dent Res. 2018; 7 (1) :8-13
URL: http://cjdr.ir/article-1-225-en.html


Volume 7, Issue 1 ( March- 2018) Back to browse issues page
مجله تحقیقات دندانپزشکی کاسپین Caspian Journal of Dental Research
Persian site map - English site map - Created in 0.09 seconds with 30 queries by YEKTAWEB 3790